詳細介紹
中空纖維超濾膜組件型號: UF-90L
性能參數(shù)
初始產(chǎn)水量----------------------------------------------------------------------------1T/H ※1 設計產(chǎn)水量----------------------------------------------------------------------------0.3-0.6T/H 產(chǎn)水污染指數(shù)( SDI) --------------------------------------------------------------﹤1 ※2 產(chǎn)水濁度-------------------------------------------------------------------------------﹤0.1NTU ※3 1nm 以上顆粒去除率---------------------------------------------------------------≥90% 去除總大腸菌群率------------------------------------------------------------------≥99.9% 去除細菌率---------------------------------------------------------------------------≥99.9% |
組件規(guī)格
組件外形尺寸-------------------------------------------------------------------------¤90×1170 組件類型-------------------------------------------------------------------------------內(nèi)壓式中空纖維膜 膜材質(zhì)----------------------------------------------------------------------------------PVC 封膠材料-------------------------------------------------------------------------------環(huán)氧樹脂 截留分子量---------------------------------------------------------------------------50000--100000 道爾頓 標準膜面積--------------------------------------------------------------------------- 4.5 ㎡ 中空纖維絲數(shù)量----------------------------------------------------------------------1300 根 中空纖維絲內(nèi)外徑------------------------- -----------------------------------------1.0/1.8 ㎜ |
建議應用數(shù)據(jù)
進水通量-------------------------------------------------------------------------------0.5-1.5T/H 進水壓力-------------------------------------------------------------------------0.3Mpa 透膜壓差-------------------------------------------------------------------------0.15Mpa 反洗透膜壓差-------------------------------------------------------------------0.15Mpa 進水溫度-------------------------------------------------------------------------45℃ 進水溫度-------------------------------------------------------------------------5℃ 瞬時余氯耐受濃度-------------------------------------------------------------------100ppm ※4 瞬時H2O2 耐受濃度------------------------------------------ ---------------------200ppm ※4 短時進水濁度-------------------------------------------------------------------200NTU 進水pH 值范--------------------------------------------------------------------------3-10 化學清洗pH---------------------------------------------------------------------------1.5-13 過濾方式------------------------------------------------------------------------------全量過濾或錯流過濾 |
典型工藝條件
反洗進水通量--------------------------------------------------------------------------0.5T/H-1.5T/H 反洗工作時間--------------------------------------------------------------------------30-60SEC 反洗頻率--------------------------------------------------------------------------------20-60MIN 化學加強反洗頻率--------------------------------------------------------------------0 – 4 次 / 天 化學加強反洗時間--------------------------------------------------------------------1-30MIN 殺菌劑-------------------------------------------------------------------NaOCl、 H2O2、 ClO2 或NH2Cl 清洗藥劑--------------------------------------------------------- HCl、 H2SO4 、 NaOH 或 Citric Acid |
注:
※1 初始產(chǎn)水量是指在 25℃, 0.1MPa 條件下過濾純水時的產(chǎn)水量;
※2 是指進水濁度<20NTU 時的測量值(原水 6~10 秒鐘堵死 SDI 測試儀膜片) ;
※3 是指進水濁度<50NTU 時的測量值;
※4 不超過 15 分鐘;
※5 這里所公開的應用限制數(shù)據(jù)僅做為一般應用參考,在特殊應用中為了達到化的性
能以及更長的使用壽命,可能應采用更保守的數(shù)據(jù);
※6 本公司超濾膜為節(jié)能、大通量型,在 0.04MPa 透膜壓力下運行便可得到滿意的產(chǎn)水通
量,故設計系統(tǒng)時建議透膜壓力設計在 0.04~0.08MPa 范圍內(nèi),設計系統(tǒng)時應對原水
中 100μm 以上顆粒先去除,系統(tǒng)采用死端過濾,定時反洗的方法來維持膜的穩(wěn)定通量,
在對超濾膜進行反沖洗時,可采用在反洗的同時進行順沖,這樣能用較少的水量,很
短的時間將膜清洗干凈,對濁度較大的水可每隔 10-20 分鐘進行一次順沖;
※7 上表中的數(shù)據(jù)僅供參考,不作為保證值;