日本HORIBA LabRAM Odyssey Semiconductor

參考價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 公司名稱上海亨東儀器有限公司
  • 品       牌
  • 型       號(hào)
  • 所  在  地上海市
  • 廠商性質(zhì)其他
  • 更新時(shí)間2023/11/22 14:07:30
  • 訪問次數(shù)141
產(chǎn)品標(biāo)簽:

在線詢價(jià) 收藏產(chǎn)品 查看電話 同類產(chǎn)品

聯(lián)系我們時(shí)請(qǐng)說明是 制藥網(wǎng) 上看到的信息,謝謝!

  上海亨東儀器有限公司是一家專注于儀器儀表、環(huán)保設(shè)備、檢測(cè)設(shè)備、電氣設(shè)備、五金工具、機(jī)械設(shè)備及配件、化工原料的開發(fā),代理,銷售和服務(wù)工作。供應(yīng)HACH哈希COD試劑,WTWBOD測(cè)定儀,哈納HANNA離子劑,Lovibond BOD測(cè)定儀,Lovibond色度儀等產(chǎn)品。公司擁有強(qiáng)大的專業(yè)技術(shù)服務(wù)支持隊(duì)伍,的銷售工程師,完善的售后服務(wù)體系,讓服務(wù)更專業(yè)、更經(jīng)濟(jì)!上海亨東儀器有限公司在儀器領(lǐng)域擁有多年的研發(fā)和市場(chǎng)推廣經(jīng)驗(yàn),并與一些院校和科研單位有著長(zhǎng)期良好的合作關(guān)系.上海亨東儀器有限公司主要提供如下產(chǎn)品:水質(zhì)分析儀品牌及檢測(cè)項(xiàng)目美國(guó)哈希HACH,德國(guó)WTW,意大利HANNA,德國(guó)LOVIBOND、德國(guó)賽多利斯、瑞士梅特勒。 PH計(jì)/酸度計(jì)、電導(dǎo)率測(cè)定儀、溶解氧測(cè)定儀、水質(zhì)離子測(cè)定儀、濁度測(cè)定儀、水質(zhì)硬度計(jì)、化學(xué)需氧量COD/生化需氧量BOD快速測(cè)定儀、余氯總氯比色儀、總氮總磷分析儀、非分散紅外測(cè)油儀/油分儀、農(nóng)藥殘毒速測(cè)儀、土壤養(yǎng)分速測(cè)儀、紫外可見分光光度計(jì)、水質(zhì)采樣器、負(fù)離子濃度測(cè)試儀、電子天平等。水質(zhì)分析儀品牌及檢測(cè)項(xiàng)目嘉興紅聲,杭州愛華,嘉興恒升,美國(guó)NK等。噪聲、振動(dòng)、氣象、風(fēng)速、電磁輻射及放射性監(jiān)測(cè)分析;電子安規(guī)測(cè)試;工業(yè)生產(chǎn)檢測(cè);以及工業(yè)衛(wèi)生和食品安全等各種用途的儀器儀表等。檢測(cè)設(shè)備、電氣設(shè)備品牌及檢測(cè)項(xiàng)目日本日置、美國(guó)luyor、中國(guó)臺(tái)灣固緯、德圖TESTO、日本圖技GRAPHTEC紅外測(cè)溫儀、涂層測(cè)厚儀、測(cè)振儀、轉(zhuǎn)速表、測(cè)溫儀、激光測(cè)距儀、測(cè)力計(jì)、兆歐表、萬用表、鉗形表、示波器、數(shù)字示波器、信號(hào)源、電源、頻譜分析儀、功率分析儀、等測(cè)試儀器.
PH計(jì)/酸度計(jì)、電導(dǎo)率測(cè)定儀、溶解氧測(cè)定儀、水質(zhì)離子測(cè)定儀、濁度測(cè)定儀、水質(zhì)硬度計(jì)、化學(xué)需氧量COD/生化需氧量BOD快速測(cè)定儀、余氯總氯比色儀、總氮總磷分析儀、非分散紅外測(cè)油儀/油分儀、農(nóng)藥殘毒速測(cè)儀、土壤養(yǎng)分速測(cè)儀、紫外可見分光光度計(jì)、水質(zhì)采樣器、負(fù)離子濃度測(cè)試儀、電子天平等
日本HORIBA LabRAM Odyssey Semiconductor半導(dǎo)體顯微鏡是在直徑達(dá)300mm的晶片上進(jìn)行光致發(fā)光和拉曼成像的理想工具。HORIBA的真共焦顯微鏡配備了自動(dòng)化300mm樣品臺(tái)和物鏡轉(zhuǎn)臺(tái),以滿足晶圓均勻性評(píng)估和缺陷檢查的需求。
日本HORIBA LabRAM Odyssey Semiconductor 產(chǎn)品信息



LabRAM Odyssey Semiconductor includes hardware and software designed for semiconductors analysis:

  • Wafer mapping with automated turret and sample stage
    The automated 300 mm × 300 mm XY sample stage accepts wafers up to 300 mm (12") diameter for Raman and Photoluminescence mapping of both full wafers and small regions of interest (ROI). The travel speed of the stage together with its stability ensure fast and reliable measurements over ROIs spread over the wafer surface.
  • Uniformity measurement with wafer tilt correction
    The “Tilt at midway” autofocus function corrects for any wafer bow and tilt, producing accurate whole wafer uniformity data, even from thin layers. This function is rapid since it determines the optimum focus height at only at five points prior to mapping: in the center and four points at midway between the center and the corners.
  • From full wafer to high resolution defect mapping with DuoScan
    DuoScan™ confocal imaging technology is a confocal imaging mode with both capabilities of variable size laser macro-spot scanning(using ultra-fast rastering mirrors) and high precision sub-micron step scanning. Macro-spot scanning is suitable for full wafer mapping while sub-micron step scanning is adapted to defect analysis.
  • PL and Raman metrology in one tool
    The availability of many excitation lasers together with the wide spectral range of the system, from deep UV to near IR, allows simultaneous measurement of photoluminescence and Raman signals in the same spectrum. PL and Raman in one tool significantly speeds up wafer characterization.
  • Methods: Easy recipe building for highly efficient characterization
    Methods will allow you to fully automate your entire Raman/PL characterization routine (acquisition, data processing, display, and analysis) providing high throughput that is manageable by metrology technicians.
    The “methods” building process is simple and intuitive : the process or metrology engineer can optimize each operation and in one click insert it into the recipe/method. Individual operations can be conveniently reordered, added or removed.
    This customization module is also aided by “templates” which is a way to save and recall a set of hardware configurations and software options.
  • ParticleFinder PF3: Automated particle characterization
    PF3 rapidly locates and chemically characterizes contaminants on a full wafer.
    PF3 automatically locates and Raman maps contamination particles. Also PF3 automatically identifies and classifies all detected impurities according to their chemical characteristics (organic, silicon, etc.).
    Statistics of morphological properties (area, perimeter, diameter, circularity, brightness, volume estimation, etc.) are also reported.



Dimensions

W × H × D (mm): 1400 × 620 × 1410

Optical microscope

Open space microscope with white light reflection illumination, camera, 5×, 10×, 100× objectives as standard. Optional motorized objective turret.

Spectral range

Standard 200 nm - 2200 nm from sample to detector (achromatic, no change of optics required).

Imaging spectrometer

  • Focal length: 800 mm.
  • Spectral resolution FWHM at 532 nm excitation wavelength ≤ 0.6 cm-1 with 1800 gr/mm and ≤ 0.3 cm-1 with 3000 gr/mm.
  • Spectral stability RMS: < 0.02 cm-1 RMS Measured on Si 520 cm-1 line.
  • Equipped with Open Electrode CCD (standard), optional EMCCD, optional InGaAs arrays detector (max. 3 detectors).

Spatial resolution

XY lateral resolution < 0.5 µm; Z axial resolution < 1.5 µm.

300 mm × 300 mm motorized stage

XY high precision encoded motorized stage (X = 300 mm, Y = 300mm) with repeatability ≤1 µm; accuracy = 1 µm; resolution (encoder) = 50 nm; minimum motor step size = 10 nm.
Z specifications: resolution (minimum step size) = 0.01 µm.
Holders for 4" (100 mm), 6" (150 mm), 8" (200 mm) and 12" (300 mm) size wafers available. Vacuum compatible wafer holders.

Lasers

User selectable: 266 nm, 325 nm, 355 nm, 405 nm, 458 nm, 473 nm, 532 nm, 633 nm, 660 nm, 785 nm, & 1064 nm. Up to 6 motorized.

DuoScan™

DuoScan™ technology for fast Laser scanning and Macrospot imaging (typical macrospot dimensions 30 µm × 30 µm with 50× objective).