Specifications |
Size Range: | 0.10μm - 1.0μm, optional ranges up to 5.0μm |
Channel Sizes: | Standard: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0μm |
Flow Rate: | 1.0 CFM (28.3 LPM) |
Counting Efficiency: | 50% @ 0.1μm; for particles > 0.15μm (per JIS) |
Light Source: | Laser Diode |
Zero Count Level: | <1 count / 5 minutes |
Concentration Limits: | 500,000 Particles / ft3 (17,150,000 / m3) @ 5% Coincidence Loss |
Calibration: | NIST Traceable, per ISO 21501-4 (Unit-to-Unit Accuracy and Repeatability) |
Count Modes: | Automatic, Manual, Beep, Concentration, Cumulative/Differential, Real Time (with LMSNet or LMS Express RT software) |
Data Storage: | 3,000 Sample Records, Rotating Buffer (particle and environmental data with location and time) |
Communication Modes: | USB, Ethernet, RS-485 and Secure Data Transfer (LSDT) to and Storage on USB Flash Drive |
Supporting Software: | LMS XChange, LMS Express and Express RT; LMS Standard; LMS Pharma; CREWin |
4-20mA Analog Sensors: | Optional Sensors (up to 4) Include Temperature/Relative Humidity, Air Velocity and Differential Pressure |
Touch Screen Display: | 5.7-inch (14.47 cm) Color, 320x240 |
Printer: | Optional, Built-in, Thermal |
Reports: | FS-209E, ISO-14644-1 and EU GMP Annex 1 |
Enclosure: | Stainless Steel |
Alarm: | Integrated Adjustable Alarm and External Alarm Connector. Alarms on Counts, Low Battery, Sensor Failure |
Sample Output: | Internally Filtered to @ 0.1μm, Optional HEPA Filtration for Cooling System Exhaust |
Vacuum Source: | Internal Pump, Automatic Flow Control |
Power: | 100-240 VAC, 50-60 Hz |
Battery: | Optional Internal Li-Ion Removeable/Rechargeable Battery |
Dimensions: | 14.65” (l) x 8” (w) x 10.4” (h) [37 x 20 x 26 cm] |
Weight: | With Battery: 26 lbs (11.8 kg) Without Battery: 23 lbs (10.43 kg) |
Environmental Conditions |
Operating: | 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing |
Storage: | 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing |
Accessories |
Included: | Operating Manual on CD; Isokinetic Sample Probe with Tripod and Tubing; Purge Filter; Power Cable and Spare Fuse; LMS XChange Software; Printer; Printer Paper |
Optional: | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Internal Removeable, Rechargeable Battery; Carrying Case with Wheels; Cleanroom Cart; Temperature/Relative Humidity Probe; Air Velocity Probe; Differential Pressure Probe; Filter Scanning Probe; High Pressure Difuser; 32-Port Universal Manifold; LMS Express and Express RT Software; LMSNet Software; Validation Documentation |